2023/6/13 电源调试,IO口正常,系统滴答定时器正常 2023/6/14 DAC输出正常,串口中断收发与ADC冲突,修改ADC 2023/6/16 串口中断收发与ADC冲突问题解决,ADC数据读取调试中 2023/6/19 ADC数据读取成功(未使用DMA中断),串口按协议发送ADC采集到的数据(中断方式) 2023/6/25 SPI功能完善,温度采集成功 2023/6/26 485收发正常 2023/6/27 位移数据丢包问题解决,但数据偶有误码,不知原因; 装置所需数据整理打包完成; 2023/7/5 接近传感器测试装置命令 命令 //05 00 14 00 A1 00 B1 F0 01 01 00 00 00 01 01 F4 03 34 CD 40 1B F0 01:基础位移测试命令字 01:0 停止 1 运行 2 运行到近端 3 运行到远端 00:0 手动 1 自动 00:0 正转 1 反转 00 01:电机运行多少圈为一个步长 01 F4:电机运行间隔时长 03 34:设定电压值 发送 //05 00 3D 00 B1 00 A1 F0 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 CD 40 1B 数据:50W 1-44W为ADC数据 45-47W为温度数据 48-49W为位移数据 50W为标志位 命令 //05 00 0C 00 A1 00 B1 F0 02 01 04 E7 1B F0 02:启动延时时间和错误信号持续时间测试命令字 01:0 1mm 1 2mm 2 3mm 3 4mm 发送 //05 00 47 00 B1 00 A1 F0 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 CD 40 1B 数据:60W 1-40W启动延时时间 41-60W错误信号持续时间 命令 //05 00 0C 00 A1 00 B1 F0 03 01 CD 40 1B F0 03:频率测试命令字 01:0 停止 1 运行 发送 //05 00 0F 00 B1 00 A1 F0 03 00 00 00 00 CD 40 1B 数据:4W 1-2W光电开关频率 3-4W接近传感器频率 命令 //05 00 0C 00 A1 00 B1 F0 04 01 CD 40 1B F0 04:找零命令字 01:0 1mm 1 2mm 2 3mm 3 4mm 发送 //05 00 3D 00 B1 00 A1 F0 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 CD 40 1B 数据:50W 1-44W为ADC数据 45-47W为温度数据 48-49W为位移数据 50W为标志位